Defender Safety System® High-Input Direct Vent Energy Saver Models
Our second-generation Direct Vent water heaters offer higher inputs and gallon capacities. Our same co-axial venting will go up to eight feet vertically and horizontally.
|
|

|
Defender Safety System features
- Advanced ScreenLok® Technology Flame Arrestor Design
- Flammable Vapor Sensor
- Maintenance Free
- Pedestal Base
Powerful Blower Motor Sight Window
- Spark to Pilot Ignition System
- Electronic Gas Control Valve
- Stainless Steel Flue Baffle
Standard Energy Saver Features
- Factory Installed Hydrojet® Total Performance System
- Vitraglas® Lining
- Factory Installed dielectric waterway fittings
- Fully automatic controls
- Flue baffle
- Protective magnesium anode rod
- Side tappings
- Snap-lock draft diverter
- T&P Relief Valve Included
- Brass drain valve
- 2" Non-CFC foam insulation (1" on M1 models)
|
|
How the Defender Safety System® Works
During normal operation, air for combustion is drawn into the water heater through the opening in the jacket. This air travels down and around the combustion chamber and enters through holes in the very bottom of the corrosion-resistant combustion chamber. The air then travels up through the oriented flame arrestor plate louvers, where the velocity of the air is increased and its direction altered. The air then mixes in a normal manner with the supplied gas and is efficiently combusted, producing very low NOx emissions. In the case where trace amounts of flammable vapors are present in the air flowing into the combustion chamber, the burner or pilot flame harmlessly ignites the vapors.
If flammable vapors are in sufficient quantity to prevent normal combustion the burner and pilot flame is shut down. Should the flammable vapors continue to the burner, the flame arrestor plate prevents the flames from traveling backwards and igniting vapors outside of the combustion chamber. The calibrated, multipurpose thermal switch recognizes this and shuts down the pilot and main burner. This switch also deactivates the burner and pilot in the unlikely event of restricted airflow caused by severe lint, dust or oil accumulation on the arrestor plate. 
The heart of Bradford White’s Defender Safety System® is the flame arrestor design of the patented ScreenLok® Technology. This precisely engineered and manufactured component is made 304L alloy stainless steel and contains up to eighteen thousand, geometrically oriented louvers. These micro dimensioned louvers increase the velocity of incoming air to the system. If flammable vapors enter this uniquely designed system and are ignited, a vector effect occurs inside of the combustion chamber. The combination of high velocity air entering the chamber and the vector effect caused by combustion will prevent any flames present in the chamber from traveling backwards through the flame arrestor plate and outside of the water heater.
The Bradford White Defender Safety System® maintains outstanding efficiency, a long service life and very low NOx emissions. Best of all, it provides maintenance free operation while meeting the stringent ANSI standard for the affected gas water heaters. |
|